Ergonomic standard
  • Abstract:
    This part of IEC 60519 specifies the general safety requirements for industrial installations or equipment intended for electroheating (EH) and electroheating based treatment technologies as well as for electromagnetic processing of materials (EPM). This document deals with the significant hazards, hazardous situations or hazardous events relevant to industrial EH and EPM equipment, as listed in Annex A, for normal operation and for single fault condition as well as under conditions of reasonably foreseeable misuse. This document specifies the requirements intended to be met by the manufacturer to ensure the safety of persons and property during the complete life cycle of the equipment from design through commissioning, operation, maintenance, inspection, to decommissioning, as well as in the event of foreseeable single fault condition that can occur in the equipment. The rated voltage of EH and EPM equipment can be in the range of low voltage; details are given in 4.2. This document does not apply to equipment and appliances within the scope of IEC 60079 (all parts) - i.e. equipment intended for use in potentially explosive atmospheres; IEC 60335 (all parts) - i.e. household, commercial and similar electrical appliances, including room heating; IEC 60601 (all parts) - i.e. medical electrical equipment; IEC 60974 (all parts) - i.e. arc welding equipment; IEC 61010 (all parts) - i.e. equipment for laboratory use. This document does not provide requirements for type testing. NOTE Industrial equipment covered by this document is typically produced as a single unit or a very small number of units; such unit usually has a very high value and can cause severe harm at disintegration. This document does not address data security and hazards arising from neglect of security.
  • Document number:
    IEC 60519-1
  • Issuing date:
    2020-03-01
  • Document type:
    Norm
  • Title:
    Safety in installations for electroheating and electromagnetic processing - Part 1: General requirements
  • Replaces:
    IEC 27/1121/FDIS(2019-11); IEC 60519-1(2015-03)
  • Author:
    IEC/TC 27 Industrial electroheating equipment
  • Search term:
    Acceptance inspection; CE marking; Commissioning; Definitions; Documentation; Electric heating; Electrical engineering; Electrical safety; Electro heating installations; Electromagnetic; Equipment; Equipment safety; Induction heating; Inductive heatings; Industrial; Industrial facilities; Industries; Magnetic fields; Maintenance; Marking; Occupational safety; Operating instructions; Operation; Protective measures; Resistance heating; Safety; Safety of products; Safety regulations; Safety requirements; Testing; Trade; Voltage range; Workplace safety
  • Application areas:
    03.01 Anlagen, Maschinen, Geräte im Allgemeinen; 03.32 Industrieöfen, Heizkessel; 37.05 Kalte/heiße Oberflächen bzw. Medien
  • Hazards:
    AB Terminologische Festlegungen in Normen mit Arbeitsschutzbezug; DA Mechanische Gefährdungen im Allgemeinen; EA Elektrische Gefährdungen im Allgemeinen; GC Schall (Lärm); GH Elektrische, magnetische und elektromagnetische Felder; GI Ionisierende Strahlungen (Röntgenstrahlungen, radioaktive Strahlung / Alpha-, Beta- und Gamma-Strahlung); GL Kontakt mit heißen oder kalten Medien (Oberflächen, Umgebungen); HA Gefährdungen durch Faktoren der Arbeits- und Arbeitsplatzgestaltung im Allgemeinen; IA Gefährdungen durch psychische Belastung und durch Mängel der Arbeitsorganisation im Allgemeinen
  • ICS:
    25.180.10 Electric furnaces
  • Price:
    330,00 EUR
  • Cross references:
    CISPR 11 (2015-06)<S>; CISPR 11 AMD 1 (2016-06)<S>; CISPR 11 AMD 2 (2019-01)<S>; IEC 60071-1 (2006-01){historisch}<S>; IEC 60071-1 AMD 1 (2010-01){historisch}<S>; IEC 60204-1 (2016-10)<S>; IEC 60204-11 (2018-07)<S>; IEC 60228 (2004-11)<S>; IEC 60335-1 (2010-05){historisch}<S>; IEC 60335-1 AMD 1 (2013-12){historisch}<S>; IEC 60335-1 AMD 2 (2016-05){historisch}<S>; IEC 60364-1 (2005-11)<S>; IEC 60364-4-41 (2005-12)<S>; IEC 60364-4-41 AMD 1 (2017-03)<S>; IEC 60364-4-42 (2010-05)<S>; IEC 60364-4-42 AMD 1 (2014-11)<S>; IEC 60364-4-44 (2007-08)<S>; IEC 60364-4-44 AMD 1 (2015-09)<S>; IEC 60364-4-44 AMD 2 (2018-01)<S>; IEC 60364-5-53 (2001-08){historisch}<S>; IEC 60364-5-53 AMD 1 (2002-04){historisch}<S>; IEC 60364-5-53 AMD 2 (2015-09){historisch}<S>; IEC 60364-5-54 (2011-03)<S>; IEC 60398 (2015-04)<S>; IEC 60445 (2017-08){historisch}<S>; IEC 60529 (1989-11)<S>; IEC 60664-1 (2007-04){historisch}<S>; IEC 60825-1 (2014-05)<S>; IEC 60865-1 (2011-10)<S>; IEC 60909-0 (2016-01)<S>; IEC 60990 (2016-05)<S>; IEC 61000-6-2 (2016-08)<S>; IEC 61000-6-7 (2014-10)<S>; IEC 61010-1 (2010-06)<S>; IEC 61082-1 (2014-10)<S>; IEC 61310-1 (2007-02)<S>; IEC 61310-2 (2007-02)<S>; IEC 61310-3 (2007-02)<S>; IEC 61508-1 (2010-04)<S>; IEC 61786-1 (2013-12)<S>; IEC 61786-2 (2014-12)<S>; IEC 61936-1 (2010-08){historisch}<S>; IEC 61936-1 AMD 1 (2014-02){historisch}<S>; IEC 62061 (2005-01){historisch}<S>; IEC 62061 AMD 1 (2012-11){historisch}<S>; IEC 62061 AMD 2 (2015-06){historisch}<S>; IEC 62471 (2006-07)<S>; IEC 82079-1 (2012-08){historisch}<S>; IEEE C 95.1 (2005){historisch}<S>; IEEE C 95.6 (2002){historisch}<S>; ISO 3864-1 (2011-04)<S>; ISO 6385 (2016-09)<S>; ISO 12100 (2010-11)<S>; ISO 13577-1 (2016-09)<S>; ISO 13577-2 (2014-09)<S>; ISO 13577-3 (2016-09)<S>; ISO 13732-1 (2006-09)<S>; ISO 13849-1 (2015-12)<S>; ISO 13850 (2015-10)<S>; ISO 13855 (2010-05)<S>; ISO 13857 (2008-03){historisch}<S>; ISO 14119 (2013-10)<S>; ISO 14120 (2015-11)<S>; ISO 14159 (2002-04)<S>; ISO 19353 (2019-01)<S>; IEC 60335-2-89 (2019-06)<G>; IEC 60417-DB (2002-10)<G>; IEC 61439-3 (2012-02)<G>; IEC 61439-3 Corrigendum 1 (2013-09)<G>; IEC 61439-3 Corrigendum 2 (2019-03)<G>; IEC 61439-4 (2012-11)<G>; IEC 61439-5 (2014-08)<G>; IEC 61439-5 Corrigendum 1 (2015-03)<G>; IEC 61439-6 (2012-05)<G>; IEC 61439-7 (2018-12)<G>; IEC 61439-7 Corrigendum 1 (2019-08)<G>; IEC 62271-1 (2017-07)<G>; IEC 62271-3 (2015-03)<G>; IEC 62271-4 (2013-08)<G>; IEC 62271-102 (2018-05)<G>; IEC 62271-107 (2019-05)<G>; IEC 62271-109 (2019-04)<G>; IEC 62271-110 (2017-10)<G>; IEC 62271-110 Corrigendum 1 (2017-12)<G>; IEC 62271-110 Corrigendum 2 (2018-02)<G>; IEC 62271-111 (2019-02)<G>; IEC 62271-201 (2014-03)<G>; IEC 62271-202 (2014-03)<G>; IEC 62271-202 Corrigendum 1 (2015-04)<G>; IEC 62271-203 (2011-09)<G>; IEC 62271-203 Corrigendum 1 (2013-07)<G>; IEC 62271-204 (2011-07)<G>; IEC 62271-205 (2008-01)<G>; IEC 62271-207 (2012-04)<G>; IEC 62271-207 Corrigendum 1 (2013-01)<G>; IEC 62271-209 (2019-02)<G>; IEC 62271-211 (2014-04)<G>; IEC 62271-211 Corrigendum 1 (2015-08)<G>; IEC 62271-211 Corrigendum 2 (2017-06)<G>; IEC 62271-212 (2016-10)<G>; IEC 62271-214 (2019-06)<G>; ISO 7000 (2019-07)<G>; ISO 7010 (2019-07)<G>; IEC 60335-2-24 (2020-09)<G>; IEC 61439-1 (2020-05)<G>; IEC 61439-2 (2020-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-100 (2021-07)<G>; IEC 62271-101 (2021-07)<G>; IEC 62271-101 (2021-07)<G>; IEC 62271-101 (2021-07)<G>; IEC 62271-101 (2021-07)<G>; IEC 62271-103 (2021-05)<G>; IEC 62271-103 (2021-05)<G>; IEC 62271-104 (2020-08)<G>; IEC 62271-105 (2021-06)<G>; IEC 62271-106 (2021-04)<G>; IEC 62271-106 (2021-04)<G>; IEC 62271-108 (2020-07)<G>; IEC 62271-112 (2021-07)<G>; IEC 62271-200 (2021-05)<G>; IEC 62271-200 (2021-05)<G>; IEC 62271-215 (2021-06)<G>
  • Cited in:
    DIN EN IEC 60519-1 (2020-12); DIN EN IEC 60519-8 (2021-02)<STARR>; DIN EN IEC 63078 (2020-10)<GLEITEND>; BS EN IEC 60519-1 (2020-06-08); BS EN IEC 60519-8 (2020-07-01); BS EN IEC 63078 (2020-03-03); EN IEC 60519-4 (2022-02)<STARR>; EN IEC 60519-8 (2020-06)<GLEITEND>; NF C79-634 (2022-02-04); NF C79-638 (2020-06-26); IEC 60519-4 (2021-12)<STARR>; IEC 60519-8 (2020-05)<GLEITEND>; OVE EN IEC 60519-8 (2021-03-01); OVE EN IEC 63078 (2020-11-01); GOST IEC 60519-3 (2016); GOST IEC 60519-4 (2015); GOST IEC 60519-6 (2016); GOST IEC 60519-8 (2015); GOST IEC 60519-9 (2016); GOST IEC 60519-10 (2015); GOST IEC 60519-12 (2016)
  • Identical with:
    DIN EN IEC 60519-1(2020-12)<IDT>; BS EN IEC 60519-1(2020-06-08)<IDT>; EN IEC 60519-1(2020-05)<IDT>; NF C79-631(2020-05-29)<IDT>; SN EN IEC 60519-1(2020-05)<IDT>; OVE EN IEC 60519-1(2021-01-01)<IDT>; PN-EN IEC 60519-1(2020-12-16)<IDT>; UNE-EN IEC 60519-1(2020-07-01)<IDT>; TS EN IEC 60519-1(2020-11-09)<IDT>