- Abstract:This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the text, except the first paragraph, with the following new text: This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document, consideration is given to those other Part 2 standards. The standard for equipment which contains heating devices is IEC 61010-2-010.
- Document number:IEC 61010-2-051
- Issuing date:2018-10-01
- Document type:Norm
- Title:Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
- Replaces:IEC 66/642/CDV(2017-12); IEC 61010-2-051(2015-03)
- Author:IEC/TC 66 Safety of measuring, control and laboratory equipment
- Search term:Agitators; CE marking; Control devices; Control equipment; Control technology; Electric appliances; Electric control equipment; Electrical engineering; Electrical measuring instruments; Electrical safety; Electrically-operated devices; Electronic engineering; Hazards; Laboratory furniture; Laboratory ware; Measuring instruments; Mixers; Mixing machines; Process measuring and control technology; Protection against electric shocks; Safety; Safety engineering; Safety regulations; Safety requirements; Specification (approval); Stirrers (laboratory); Stirring machines; Test equipment
- Application areas:09.05 Medizinische Geräte und Instrumente
- Hazards:DA Mechanische Gefährdungen im Allgemeinen; EA Elektrische Gefährdungen im Allgemeinen; FA Brand- und Explosionsgefährdungen im Allgemeinen
- ICS:19.080 Electrical and electronic testing; 71.040.20 Laboratory ware and related apparatus; 71.040.50 Physicochemical methods of analysis
- Price:40,00 EUR
- Cited in:DIN EN IEC 60335-2-110 (2022-08); DIN EN IEC 60519-1 (2020-12); DIN EN 60601-1 (2022-11); DIN EN 61010-031 (2023-02); DIN EN IEC 61326-1 (2022-11); DIN EN IEC 61784-1 (2020-08)<GLEITEND>; DIN EN 62446-1 (2019-04)<GLEITEND>; DIN EN ISO 23553-1 (2022-08); DIN EN ISO 23553-1 (2022-12); DIN EN ISO 27427 (2020-02); 18/30387971 DC (2018-11-30); 19/30381327 DC (2019-08-12); 20/30370861 DC (2020-02-27); 20/30398805 DC (2020-05-22); 21/30396844 DC (2021-03-19); 21/30431302 DC (2021-01-29); 21/30441897 DC (2021-08-05); 22/30442345 DC (2022-05-12); 22/30451242 DC (2022-01-26); BS ISO 15190 (2020-03-03); BS EN IEC 60335-2-110 (2021-10-21); BS EN IEC 60519-1 (2020-06-08); BS EN IEC 61326-1 (2021-06-07); BS EN IEC 61784-1 (2019-06-11); PD IEC/TR 60601-4-3 (2019-01-04); EN IEC 61784-1 (2019-05)<GLEITEND>; EN IEC 61784-1-3 (2023-04)<GLEITEND>; IEC 60688 (2021-09)<GLEITEND>; IEC 61784-1 (2019-04)<GLEITEND>; IEC 61784-1-3 (2023-03)<GLEITEND>; OVE EN IEC 61784-1 (2020-09-01); OVE EN 62446-1 (2019-05-01); TÜV-VERBAND BP UEBF 0100-2-RL (2000-12)<GLEITEND>; TÜV-VERBAND BP UEBF 0100-3-RL (2000-12)<GLEITEND>
- Identical with:DIN EN IEC 61010-2-051(2023-01)<MOD>; ANSI/UL 61010-2-051(2019)<IDT>; BS EN IEC 61010-2-051+A11(2021-11-04)<MOD>; EN IEC 61010-2-051(2021-09)<IDT>; NF C42-020-2-051(2021-09-10)<IDT>; CSA C22.2 No. 61010-2-051(2019-08-01)<MOD>; CSA C22.2 No. 61010-2-101(2019-08-01)<MOD>; OVE EN IEC 61010-2-051(2023-02-01)<NEQ>; UNE-EN IEC 61010-2-051(2021-10-01)<IDT>; KS C IEC 61010-2-051(2019-12-30)<IDT>; TS EN IEC 61010-2-051(2021-09-30)<IDT>; UL 61010-2-051(2019-06-27)<IDT>
- Update flag:Unchanged