Full display

show table of content
  • Abstract:
    1.1 Scope of EN 1999 1 5(1) EN 1999 15 applies to the structural design of aluminium structures, stiffened and unstiffened, that have the form of a shell of revolution or of a round panel in monocoque structures.(2) EN 1999 15 covers additional provisions to those given in the relevant parts of EN 1999 for design of aluminium structures.NOTE Supplementary information for certain types of shells is given in EN 1993 16 and the relevant application parts which include:- Part 3-1 for towers and masts;- Part 3-2 for chimneys;- Part 4-1 for silos;- Part 4-2 for tanks;- Part 4-3 for pipelines.(4) The provisions in EN 1999 15 apply to axisymmetric shells (cylinders, cones, spheres) and associated circular or annular plates, beam section rings and stringer stiffeners, where they form part of the complete structure.(5) Single shell panels (cylindrical, conical or spherical) are not explicitly covered by EN 1999 15. However, the provisions can be applicable if the appropriate boundary conditions are duly taken into account.(6) Types of shell walls covered in EN 1999 15 can be (see Figure 1.1):- shell wall constructed from flat rolled sheet with adjacent plates connected with butt welds, termed ‘isotropic';- shell wall with lap joints formed by connecting adjacent plates with overlapping sections, termed lap-jointed;- shell wall with stiffeners attached to the outside, termed ‘externally stiffened' irrespective of the spacing of stiffeners;- shell wall with the corrugations running up the meridian, termed ‘axially corrugated';- shell wall constructed from corrugated sheets with the corrugations running around the shell circumference, termed ‘circumferentially corrugated'. a) Elevation b) PlanIsotropic(unstiffened) Lap-jointed Externallystiffened Axially corrugated Circumferentially corrugatedFigure 1.1 - Illustration of cylindrical shell forms(7) The provisions of EN 1999 15 are intended to be applied within the temperature range defined in EN 1999 11. The maximum temperature is restricted so that the influence of creep can be neglected. For structures subject to elevated temperatures associated with fire see EN 1999 1 2.(8) EN 1999 15 does not cover the aspect of leakage.1.2 Assumptions(1) The general assumptions of EN 1990 apply.(2) The provisions of EN 1999 11 apply.(3) The design procedures are valid only when the requirements for execution in EN 1090 3 or other equivalent requirements are complied with.(4) For the design of new structures, prEN 1999 is intended to be used, for direct application, together with EN 1990, EN 1991, EN 1992, EN 1993, EN 1994, EN 1995, EN 1997, EN 1998 and EN 1999.(5) EN 1999 is intended to be used in conjunction with:- European Standards for construction products relevant for aluminium structures- EN 1090 1: Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components- EN 1090 3: Execution of steel structures and aluminium structures - Part 3: Technical requirements for aluminium structures
  • Document number:
    DIN EN 1999-1-5
  • Issuing date:
    2021-04-01
  • Document type:
    Norm-Entwurf
  • Title:
    Eurocode 9: Design of aluminium structures - Part 1-5: Shell structures; German and English version prEN 1999-1-5:2021
  • Author:
    DIN Standards Committee Building and Civil Energeering
  • Search term:
    Aluminium; Aluminium construction; Application rule; Buckling of sheels; Buildings; Changes of temperature; Civil engineering; Cladding; Classification; Climatic; Climatic loading; Components; Construction; Containers; Definitions; Design; Dimensioning; Durability; Effects; Eurocode; Fire protection; Fire resistance; Fitness for purpose; Geometry; Influence of temperature; Isothermal; Materials; Mathematical calculations; Mechanical hazards; Safety against bulging; Safety requirements; Specification (approval); Stress; Stressed-skin structures; Structural engineering drawings; Structures; Temperature; Temperature differences; Thermal effects; Thermodynamic properties
  • Application areas:
    08.15 Bauten, Gebäude, Schutzbauten; 08.20 Baustrukturen; 08.35 Ingenieurbau und Ingenieurbauwerke
  • Hazards:
    AB Terminologische Festlegungen in Normen mit Arbeitsschutzbezug; AC Mess- und Prüfverfahren für die Ermittlung von Belastungen und Gefährdungen; HB Klima (Temperatur, Feuchtigkeit, Luftströmung, Luftzusammensetzung u. Ä.)
  • ICS:
    91.010.30 Technical aspects; 91.080.17 Aluminium structures
  • Price:
    189,10 EUR
  • Identical with:
    prEN 1999-1-5(2021-03)<IDT>
  • Update flag:
    Unchanged
  • Deadline for comments: