- Abstract:This standard contains an Application Guide which supports the European Standards EN 50526-1 and EN 50526-2. Guidance is offered on the subjects selection and installation of surge arresters, selection and installation of voltage limiting devices as VLD-O and VLD-F as well as arrangement of the surge arresters and VLDs.
- Document number:DIN EN 50526-3; VDE 0115-526-3
- Issuing date:2017-01-01
- Document type:Norm
- Title:Railway application - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 3: Application Guide; German version EN 50526-3:2016
- Replaces:DIN EN 50526-3(2014-06)
- Author:German Commission for Electrical, Electronic and Information Technologies of DIN and VDE
- Search term:Application rule; Applications; Classification; Definitions; Direct current; Direct current installations; Direct-current convertors; Earthing; Electric power systems; Electrical engineering; Electrical transmission systems; Locomotive haulage; Low voltage; Marking; Metal oxide arresters; Metallic oxides; Overcurrent detectors; Overvoltage limiter; Protection devices; Qualification tests; Rail tracks; Rail transport; Railway applications; Railway electric traction equipment; Railway engineering; Railway fixed equipment; Railway installations; Railways; Routine check tests; Setting-up conditions; Specification (approval); Stationary; Supply voltages; Surge arresters; Switchgear; Switchgears; Testing; Traction current supply plants; Voltage; Voltage limitation
- Application areas:04.45 Elektrische Schutzelemente (Sicherungen, Überspannungsschutzeinrichtungen, Fehlerstromschutzschalter u. Ä.); 06.20 Fahrzeuge, Fahrzeugteile
- Hazards:AB Terminologische Festlegungen in Normen mit Arbeitsschutzbezug; EA Elektrische Gefährdungen im Allgemeinen
- ICS:29.120.50 Fuses and other overcurrent protection devices; 29.280 Electric traction equipment
- Price:107,03 EUR
- Cross references:EN 50122-1 (2011-01){historisch}<S>; EN 50122-2 (2010-10){historisch}<S>; EN 50123-2 (2003-02)<S>; EN 50123-7-1 (2003-02)<S>; EN 50124-1 (2001-03){historisch}<S>; EN 50163 (2004-11)<S>; EN 50526-1 (2012-01)<S>; EN 50526-2 (2014-02)<S>; IEC 60050-195 (1998-08){historisch}<S>; IEC 60050-441 (1984)<S>; IEC 60050-604 (1987){historisch}<S>; IEC 60050-811 (1991-09){historisch}<S>; EN 62305-2 (2012-05)<G>; DIN EN 50123-2 (2003-11); DIN EN 50123-7-1 (2003-10); DIN EN 50163 (2005-07); DIN EN 50526-1 (2012-05); DIN EN 50526-2 (2014-07); DIN EN 60099-4 (2015-07); DIN EN 62305-1 (2011-10); DIN EN 50119 (2021-01); DIN EN 50122-1 (2023-02); DIN EN 50122-2 (2023-03); DIN EN 50124-1 (2017-12)
- Cited in:DIN EN 50119 (2021-01); DIN EN 50122-2 (2023-03)
- Identical with:EN 50526-3(2016-01)<IDT>
- Update flag:Unchanged