- Abstract:The DIN 18008 series of standards specifies rules for the design and construction of glass construction products. Part 6 deals with additional requirements for glazings that are accessed for maintenance purposes or are break-proof. The standard does not deal with aspects of health and safety in the workplace. Accessible glazing of this type can be supported linearly or point-fixed. The structural boundary conditions for linearly supported glazing stated in Part 2 of DIN 18008 and those for point-fixed glazing stated in Part 3 of DIN 18008 shall be taken into account.
- Document number:DIN 18008-6
- Issuing date:2018-02-01
- Document type:Norm
- Title:Glass in building - Design and construction rules - Part 6: Additional requirements for walk-on glazing in case of maintenance procedures and for fall-through glazing
- Replaces:DIN 18008-6(2015-02)
- Author:DIN Standards Committee Building and Civil Energeering
- Search term:Accessibility; Constructional products; Definitions; Dimensioning; Fall-trough protection; Glass for building purposes; Glazing; Load capacity; Load measurement; Maintenance work; Materials; Safety devices; Sealed units; Workplace safety
- Application areas:08.05 Bauwerksteile (Decken, Wände, Treppen, Türen, Fenster, Fußböden und Bodenbelege u. Ä.)
- Hazards:AB Terminologische Festlegungen in Normen mit Arbeitsschutzbezug; DF Stürzen, Rutschen, Stolpern, Fallen
- ICS:81.040.20 Glass in building
- Price:82,20 EUR
- Cross references:DIN 18008-4 (2013-07)<S>; DIN 4426 (2017-01)<G>; DIN 18008-3 (2013-07)<G>; DIN 71752 (1994-04)<G>; DIN EN 1990/NA (2010-12)<G>; DIN EN 1991-1-1 (2010-12)<G>; DIN EN 1991-1-1/NA (2010-12)<G>; DIN EN 1991-1-1/NA/A1 (2015-05)<G>; DIN EN 1991-1-2 (2010-12)<G>; DIN EN 1991-1-2 Berichtigung 1 (2013-08)<G>; DIN EN 1991-1-2/NA (2015-09)<G>; DIN EN 1991-1-3 (2010-12)<G>; DIN EN 1991-1-3/A1 (2015-12)<G>; DIN EN 1991-1-4 (2010-12)<G>; DIN EN 1991-1-4/NA (2010-12)<G>; DIN EN 1991-1-5 (2010-12)<G>; DIN EN 1991-1-5/NA (2010-12)<G>; DIN EN 1991-1-6 (2010-12)<G>; DIN EN 1991-1-6 Berichtigung 1 (2013-08)<G>; DIN EN 1991-1-6/NA (2010-12)<G>; DIN EN 1991-1-7 (2010-12)<G>; DIN EN 1991-1-7/A1 (2014-08)<G>; DIN EN 1991-2 (2010-12)<G>; DIN EN 1991-2/NA (2012-08)<G>; DIN EN 1991-3 (2010-12)<G>; DIN EN 1991-3 Berichtigung 1 (2013-08)<G>; DIN EN 1991-4 (2010-12)<G>; DIN EN 1991-4 Berichtigung 1 (2013-08)<G>; DIN EN 1991-4/NA (2010-12)<G>; DIN 1259-1 (2001-09)<G>; DIN 1259-2 (2001-09)<G>; DIN 18008-1 (2020-05)<G>; DIN 18008-2 (2020-05)<G>; DIN EN 1990 (2021-10)<G>; DIN EN 1991-1-3/NA (2019-04)<G>; DIN EN 1991-1-7/NA (2019-09)<G>; DIN EN 1991-3/NA (2019-02)<G>; DIN EN 12150-1 (2020-07)<G>; DIN ISO 8930 (1991-03)<G>; ISO 6707-1 (2020-08)<G>
- Cited in:DIN 18008-1 (2020-05)<STARR>; DIN 18055 (2020-09); DIN 18360 (2019-09)<GLEITEND>; ift-Leitfaden Montage, Vorhangfassaden (2022-03); RAL-GZ 716 (2019-04); RAL-GZ 966 (2018-07); STLB-Bau LB 021 DVD (2022-10)<STARR>; TR Glas 3 (2021){historisch}; TR Glas 26 (2020); VFF Merkblatt V.05 (2020-03); MTBauBestVV (2021-01-19)<STARR>; MTBauBestVV (2021-11-19){historisch}<STARR>; MTBauBestVV (2022-01-17)<STARR>; TBauBestVerzVV SH (2020-02-05){historisch}<STARR>
- Update flag:Unchanged