Full display

  • Abstract:
    This part of IEC 60951 provides general guidance on the design principles and performance criteria for equipment for continuous high range area gamma monitoring in nuclear facilities for accident and post-accident conditions. This standard categorizes accident condition into design basis accidents (DBAs) and design extension conditions (DECs).
  • Document number:
    DIN IEC 60951-3; VDE 0491-14-3
  • Issuing date:
    2020-11-01
  • Document type:
    Norm-Entwurf
  • Title:
    Nuclear facilities - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 3: Equipment for continuous high range area gamma monitoring (IEC 45A/1325/CD:2020); Text in German and English
  • Author:
    German Commission for Electrical, Electronic and Information Technologies of DIN and VDE
  • Search term:
    Accidents; Beta radiation; Criterion; Design; Dose; Dosimetry; Electrical engineering; Gamma-radiation; Incidents; Inspection; Installation; Installations; Instrumentation; Monitoring; Monitoring device; Neutron radiation; Nuclear energy; Nuclear installations; Nuclear power plants; Nuclear radiation; Nuclear reactors; Nuclear safety; Nuclear technology; Performance; Performance tests; Radiation; Radiation dose; Radiation measurement; Radiation monitoring; Specification (approval); Surveillance (approval); Testing
  • Application areas:
    20.01 Stoffe und Zubereitungen im Allgemeinen
  • Hazards:
    AC Mess- und Prüfverfahren für die Ermittlung von Belastungen und Gefährdungen; GI Ionisierende Strahlungen (Röntgenstrahlungen, radioaktive Strahlung / Alpha-, Beta- und Gamma-Strahlung)
  • ICS:
    17.240 Radiation measurements; 27.120.20 Nuclear power plants. Safety
  • Price:
    16,05 EUR
  • Cited in:
    DIN IEC 61504 (2022-05)
  • Identical with:
    IEC 45A/1325/CD(2020-03)<IDT>
  • Update flag:
    Unchanged